留言板

尊敬的读者、作者、审稿人, 关于本刊的投稿、审稿、编辑和出版的任何问题, 您可以本页添加留言。我们将尽快给您答复。谢谢您的支持!

姓名
邮箱
手机号码
标题
留言内容
验证码
刘冬燕, 赵敏, 林文鹏. 黑臭水体生物修复中各粒级浮游植物与环境因子的关系[J]. 水生生物学报, 2009, 33(3): 418-425.
引用本文: 刘冬燕, 赵敏, 林文鹏. 黑臭水体生物修复中各粒级浮游植物与环境因子的关系[J]. 水生生物学报, 2009, 33(3): 418-425.
LIU DongYan, ZHAO Min, LIN WenPeng. RELATIONSHIP OF ALL SIZE-FRACTIONATED PHYTOPLANKTON WITH ENVIRON-MENTAL FACTORS AFTER BIOREMEDIATION IN BLACK AND FECULENT WATER[J]. ACTA HYDROBIOLOGICA SINICA, 2009, 33(3): 418-425.
Citation: LIU DongYan, ZHAO Min, LIN WenPeng. RELATIONSHIP OF ALL SIZE-FRACTIONATED PHYTOPLANKTON WITH ENVIRON-MENTAL FACTORS AFTER BIOREMEDIATION IN BLACK AND FECULENT WATER[J]. ACTA HYDROBIOLOGICA SINICA, 2009, 33(3): 418-425.

黑臭水体生物修复中各粒级浮游植物与环境因子的关系

RELATIONSHIP OF ALL SIZE-FRACTIONATED PHYTOPLANKTON WITH ENVIRON-MENTAL FACTORS AFTER BIOREMEDIATION IN BLACK AND FECULENT WATER

  • 摘要: 通过对黑臭水体生物修复过程中水体理化指标以及浮游植物粒经分级叶绿素a的分析,探讨了水体生物修复对理化因子的影响以及各粒级浮游植物与理化因子的关系。生物修复实施后,各试验组CODCr和BOD5均呈下降趋势,试验组C、D、E的氨氮、总氮和总磷净化效果均较显著,氨氮去除率分别达到71.3%、84.0%和93.2%,总氮去除率分别达到45.2%、64.6%和78.0%,总磷下降幅度分别达到46.2%、50.3%和75.5%。其中,试验组理化环境改善最佳的组为E组,其CODCr、NH4和TP指标均较对照组A有明显下降(p0.05)。Netphytoplankton Chla%与CODCr、TN、NH4和TP呈非常显著的负相关(p0.01),与NO2-N和NO3-N呈非常显著的正相关;而Nanophytoplankton Chla%和Picophytoplankton Chla%对上述环境因子的响应与Netphytoplankton Chla%相反。

     

    Abstract: The relationships between organism and its surroundings have been widely adopted to evaluate the health of eco-system. Through the analysis of the size-fractionated phytoplankton in black and feculent water, it discussed the effect of bioremediation on all size-fractionated phytoplankton and the relationship of all size-fractionated chlorophyll-α with envi-ronmental factors to bioremediation, so as to provide biological proof for illustrating the efficiency of measures taken for the bioremediation.Comprehensive measures concerning ecology including the way of adding bioenergizer, biologic algaecide, effective microbe into water, and planting macrophyte are adopted. Group A is the contrast group, does not use any measures; Group B, C, D, E, F and G are test groups. Group B add photosynthetic bacteria and nitrifying bacteria; Group C add photosynthetic bacteria nitrifying bacteria and oxygen strengthen; Group D add photosynthetic bacteria nitrifying bacteria bioenergizer and oxygen strengthen; Group E add photosynthetic bacteria nitrifying bacteria bioenergizer plant Eichhornia crassipes and oxygen strengthen; Group F add photosynthetic bacteria nitrifying bacteria bioenergizer and plant Eichhornia crassipes; Group G add bioenergizer and oxygen strengthen. Beforehand, background was sampled twice on 28th of August in 2002. The experiment began from August 29, 2002. And after the engineering project, samples for water quality analyses were collected on the 29th and 31st of August, the 3rd, 6th, 9th, 12th and 17th of September respectively. Water samples for phytoplankton analyses were collected with length Niskin bottles (for a total final volume of 10L). The samples were divided into Pico (0.2-2.0 μm), Ultra (0.2-5 μm), Nano (2-20 μm) and Net (20-200 μm) size fractions by filtration. Chlorophyll-a was determined by spectrophotometry following the methods proposed by Lorenzen on the 9th, 12th and 17th of September in 2002 respectively. Within the periods of this survey, both of CODcr and BOD5 lowered after bioremediation and the effect of cleansing were very significantly in group C, D and E, the removal rates of NH, were 71.3%, 84.0% and 93.2%; TP were 5.2%, 64.6% and 78.0%; TN were 46.2%, 50.3% and 75.5% separately in the three groups and the effect of group E was the best. CODcr, NH, and TP were decreased significantly compared with the contrast group A (p<0.05). Bivari-ate correlate analyze was done between the content of all size-fractionated chlorophyll-a, the percentages of all size frac-tionated contents to bulk contents with all environmental factors. The result showed that the percentages of Net-Chla% significantly negatively correlated with CODcr,TN, NH, and TP and positively with NO2-N and NO3-N, while the percentage of Nano-Chla% and Pico-Chla% positively correlated with CODcr, TN, NH, and TP and negatively with NO2-N and NO3-N. As both of the TN and NH4, TP and COD are indexes reflecting the level of the water contamination, results of the above analysis signified that the percentage of Nano-and Net-chla were closely correlated with the level of water contamination.

     

/

返回文章
返回